Unknown

Dataset Information

Reliability of peak exercise testing in patients with heart failure with preserved ejection fraction.


ABSTRACT: Exercise intolerance is the primary symptom in patients with heart failure and preserved ejection fraction (HFpEF), a major determinant of their decreased quality of life, and an important outcome in clinical trials. Although cardiopulmonary exercise testing (CPET) provides peak and submaximal diagnostic indexes, the reliability of peak treadmill CPET in patients >55 years of age with HFpEF has not been examined. Two CPETs were performed in 52 patients with HFpEF (70 ± 7 years old). The 2 tests were separated by an average of 23 ± 13 days (median 22) and performed under identical conditions, with no intervention or change in status between visits except for initiation of a placebo run-in. A multistep protocol for patient screening, education, and quality control was used. Mean peak oxygen

SUBMITTER: Scott JM 

PROVIDER: S-EPMC3511643 | biostudies-literature | 2012 Dec