ABSTRACT: Objective
Tight blood glucose control (TGC) in critically ill patients is difficult and labor intensive, resulting in poor efficacy of glycemic control and increased hypoglycemia rate. The LOGIC-Insulin computerized algorithm has been developed to assist nurses in titrating insulin to maintain blood glucose levels at 80-110 mg/dL (normoglycemia) and to avoid severe hypoglycemia (<40 mg/dL). The objective was to validate clinically LOGIC-Insulin relative to TGC by experienced nurses.Research design and methods
The investigator-initiated LOGIC-1 study was a prospective, parallel-group, randomized, controlled clinical trial in a single tertiary referral center. A heterogeneous mix of 300 critically ill patients were randomized, by concealed computer allocation, to either nurse
SUBMITTER: Van Herpe T
PROVIDER: S-EPMC3554274 | biostudies-literature | 2013 Feb