Contrast enhanced ultrasound: Roles in immediate post-procedural and 24-h evaluation of the effectiveness of thermal ablation of liver tumors.


ABSTRACT:

Purpose

To retrospectively assess the diagnostic accuracy of immediate post-procedural CEUS, 24-h CEUS, and 24-h CT in verifying the effectiveness of thermal ablation of liver tumors ablation, using the combined results of 3-month post-procedure CEUS and MDCT as the reference standard.

Materials and methods

From our database, we selected patients who had immediate post-procedural CEUS and 24-h CEUS and MDCT examinations after undergoing thermal ablation of a liver tumor between January 2009 and March 2010. The study population consisted of 53 subjects and 55 tumors (44 HCC and 11 metastasis) were evaluated. Thirty-seven tumors were treated with radiofrequency and 18 with microwave ablation. Post-procedural CEUS, 24-h CEUS and MDCT, and 3-month follow-up CEUS and MDCT images