Unknown

Dataset Information

Novel biaxial tensile test for studying aortic failure phenomena at a microscopic level.


ABSTRACT:

Background

An aortic aneurysm is a local dilation of the aorta, which tends to expand and often results in a fatal rupture. Although larger aneurysms have a greater risk of rupture, some small aneurysms also rupture. Since the mechanism of aortic rupture is not well understood, clarification of the microstructure influencing the failure to rupture is important. Since aortic tissues are stretched biaxially in vivo, we developed a technique to microscopically observe the failure of an aortic rupture during biaxial stretch.

Methods

A thinly sliced porcine thoracic aortic specimen was adhered to a circular frame and pushed onto a cylinder with a smaller diameter to stretch the specimen biaxially. To induce failure to rupture at the center, the specimen was thinned at the center

SUBMITTER: Sugita S 

PROVIDER: S-EPMC3560224 | biostudies-literature | 2013 Jan

REPOSITORIES: biostudies-literature