Project description:The indoor microbiome is a complex system that is thought to depend on dispersal from the outdoor biome and the occupants' microbiome combined with selective pressures imposed by the occupants' behaviors and the building itself. We set out to determine the pattern of fungal diversity and composition in indoor air on a local scale and to identify processes behind that pattern. We surveyed airborne fungal assemblages within 1-month time periods at two seasons, with high replication, indoors and outdoors, within and across standardized residences at a university housing facility. Fungal assemblages indoors were diverse and strongly determined by dispersal from outdoors, and no fungal taxa were found as indicators of indoor air. There was a seasonal effect on the fungi found in both indoor and outdoor air, and quantitatively more fungal biomass was detected outdoors than indoors. A strong signal of isolation by distance existed in both outdoor and indoor airborne fungal assemblages, despite the small geographic scale in which this study was undertaken (<500 m). Moreover, room and occupant behavior had no detectable effect on the fungi found in indoor air. These results show that at the local level, outdoor air fungi dominate the patterning of indoor air. More broadly, they provide additional support for the growing evidence that dispersal limitation, even on small geographic scales, is a key process in structuring the often-observed distance-decay biogeographic pattern in microbial communities.
Project description:Human occupants are an important source of microbes in indoor environments. In this study, we used DNA sequencing of filter samples to assess the fungal and bacterial composition of air in an environmental chamber under different levels of occupancy, activity, and exposed or covered carpeting. In this office-like, mechanically ventilated environment, results showed a strong influence of outdoor-derived particles, with the indoor microbial composition tracking that of outdoor air for the 2-hour sampling periods. The number of occupants and their activity played a significant but smaller role influencing the composition of indoor bioaerosols. Human-associated taxa were observed but were not particularly abundant, except in the case of one fungus that appeared to be transported into the chamber on the clothing of a study participant. Overall, this study revealed a smaller signature of human body-associated taxa than had been expected based on recent studies of indoor microbiomes, suggesting that occupants may not exert a strong influence on bioaerosol microbial composition in a space that, like many offices, is well ventilated with air that is moderately filtered and moderately occupied.
Project description:The human behavioral modification recommendations during wildfire events are based on particulate matter and may be confounded by the potential risks of gas-phase pollutants such as polycyclic aromatic hydrocarbons (PAHs). Moreover, the majority of adults spend over 90 percent of their time indoors where there is an increased concern of indoor air quality during wildfire events. We address these timely concerns by evaluating paired indoor and outdoor PAH concentrations in residential locations and their relationship with satellite model-based categorization of wildfire smoke intensity. Low-density polyethylene passive air samplers were deployed at six urban sites for 1 week in Eugene, Oregon with matched indoor and outdoor samples and 24 h time resolution. Samples were then quantitatively analyzed for 63 PAH concentrations using gas-chromatography-tandem mass spectrometry. A probabilistic principal components analysis was used to reduce all 63 PAHs into an aggregate measure. Linear regression of the first principal component against indoor versus outdoor shows that indoor gas-phase PAH concentrations are consistently equal to or greater than outdoor concentrations. Regression against a satellite-based model for wildfire smoke shows that outdoor, but not indoor gas-phase PAH concentrations are likely associated with wildfire events. These results point toward the need to include gas-phase pollutants such as PAHs in air pollution risk assessment.
Project description:Air quality impacts from wildfires are poorly understood, particularly indoors. As frequencies increase, it is important to optimize methodologies to understand and reduce chemical exposures from wildfires. Public health recommendations use air quality estimates from outdoor stationary air monitors, discounting indoor air conditions, and do not consider chemicals in the vapor phase, known to elicit adverse effects. We investigated vapor-phase polycyclic aromatic hydrocarbons (PAHs) in indoor and outdoor air before, during, and after wildfires using a community-engaged research approach. Paired passive air samplers were deployed at 15 locations across four states. Twelve unique PAHs were detected only in outdoor air during wildfires, highlighting a PAH exposure mixture for future study. Heavy-molecular-weight (HMW) outdoor PAH concentrations and average Air Quality Index (AQI) values were positively correlated (p < 0.001). Indoor PAH concentrations were higher in 77% of samples across all sampling events. Even during wildfires, 58% of sampled locations still had higher indoor PAH air concentrations. When AQI values exceeded 140 (unhealthy for sensitive groups), outdoor PAH concentrations became similar to or higher than indoors. Cancer and noncancer inhalation risk estimates from vapor-phase PAHs were higher indoors than outdoors, regardless of the wildfire impact. Consideration of indoor air quality and vapor-phase PAHs could inform public health recommendations regarding wildfires.
Project description:Viruses play important roles in microbial ecology and some infectious diseases, but relatively little is known about concentrations, sources, transformation, and fate of viruses in the atmosphere. We have measured total airborne concentrations of virus-like and bacteria-like particles (VLPs between 0.02 μm and 0.5 μm in size and BLPs between 0.5 μm and 5 μm) in nine locations: a classroom, a daycare center, a dining facility, a health center, three houses, an office, and outdoors. Indoor concentrations of both VLPs and BLPs were ~105 particles m-3, and the virus-to-bacteria ratio was 0.9 ± 0.1 (mean ± standard deviation across different locations). There were no significant differences in concentration between different indoor environments. VLP and BLP concentrations in outdoor air were 2.6 and 1.6 times higher, respectively, than in indoor air. At the single outdoor site, the virus-to-bacteria ratio was 1.4.
Project description:The removal of indoor and outdoor air pollutants is crucial to prevent environmental and health issues. Photocatalytic building materials are an energy-sustainable technology that can completely oxidize pollutants, improving in situ the air quality of contaminated sites. In this work, different photoactive TiO2 catalysts (anatase or modified anatase) and amounts were used to formulate photocatalytic paints in replacement of the normally used TiO2 (rutile) pigment. These paints were tested in two different experimental systems simulating indoor and outdoor environments. In one, indoor illumination conditions were used in the photoreactor for the oxidation of acetaldehyde achieving conversions between 37 and 55%. The other sets of experiments were performed under simulated outdoor radiation for the degradation of nitric oxide, resulting in conversions between 13 and 35%. This wide range of conversions made it difficult to directly compare the paints. Thus, absorption, photonic, and quantum efficiencies were calculated to account for the paints photocatalytic performance. It was found that the formulations containing carbon-doped TiO2 presented the best efficiencies. The paint with the maximum amount of this photocatalyst showed the highest absorption and photonic efficiencies. On the other hand, the paint with the lowest amount of carbon-doped TiO2 presented the highest value of quantum efficiency, thus becoming the optimal formulation in terms of energy use.
Project description:BackgroundAir pollution is both a sensory blight and a threat to human health. Inhaled environmental pollutants can be naturally occurring or human-made, and include traffic-related air pollution (TRAP), ozone, particulate matter (PM) and volatile organic compounds, among other substances, including those from secondhand smoking. Studies of air pollution on reproductive and endocrine systems have reported associations of TRAP, secondhand smoke (SHS), organic solvents and biomass fueled-cooking with adverse birth outcomes. While some evidence suggests that air pollution contributes to infertility, the extant literature is mixed, and varying effects of pollutants have been reported.Objective and rationaleAlthough some reviews have studied the association between common outdoor air pollutants and time to pregnancy (TTP), there are no comprehensive reviews that also include exposure to indoor inhaled pollutants, such as airborne occupational toxicants and SHS. The current systematic review summarizes the strength of evidence for associations of outdoor air pollution, SHS and indoor inhaled air pollution with couple fecundability and identifies gaps and limitations in the literature to inform policy decisions and future research.Search methodsWe performed an electronic search of six databases for original research articles in English published since 1990 on TTP or fecundability and a number of chemicals in the context of air pollution, inhalation and aerosolization. Standardized forms for screening, data extraction and study quality were developed using DistillerSR software and completed in duplicate. We used the Newcastle-Ottawa Scale to assess risk of bias and devised additional quality metrics based on specific methodological features of both air pollution and fecundability studies.OutcomesThe search returned 5200 articles, 4994 of which were excluded at the level of title and abstract screening. After full-text screening, 35 papers remained for data extraction and synthesis. An additional 3 papers were identified independently that fit criteria, and 5 papers involving multiple routes of exposure were removed, yielding 33 articles from 28 studies for analysis. There were 8 papers that examined outdoor air quality, while 6 papers examined SHS exposure and 19 papers examined indoor air quality. The results indicated an association between outdoor air pollution and reduced fecundability, including TRAP and specifically nitrogen oxides and PM with a diameter of ≤2.5 µm, as well as exposure to SHS and formaldehyde. However, exposure windows differed greatly between studies as did the method of exposure assessment. There was little evidence that exposure to volatile solvents is associated with reduced fecundability.Wider implicationsThe evidence suggests that exposure to outdoor air pollutants, SHS and some occupational inhaled pollutants may reduce fecundability. Future studies of SHS should use indoor air monitors and biomarkers to improve exposure assessment. Air monitors that capture real-time exposure can provide valuable insight about the role of indoor air pollution and are helpful in assessing the short-term acute effects of pollutants on TTP.
Project description:Identifying the mechanisms that underlie the assembly of plant communities is critical to the conservation of terrestrial biodiversity. However, it is seldom measured or quantified how much deterministic versus stochastic processes contribute to community assembly in alpine meadows. Here, we measured the decay in community similarity with spatial and environmental distance in the Zoige Plateau. Furthermore, we used redundancy analysis (RDA) to divide the variations in the relative abundance of plant families into four components to assess the effects of environmental and spatial. Species assemblage similarity liner declined with geographical distance (p < .001, R 2 = .6388), and it decreased significantly with increasing distance of total phosphorus (TP), alkali-hydrolyzable nitrogen (AN), available potassium (AK), nitrate nitrogen (NO3 +-N), and ammonia nitrogen (NH4 +-N). Environmental and spatial variables jointly explained a large proportion (55.2%) of the variation in the relative abundance of plant families. Environmental variables accounted for 13.1% of the total variation, whereas spatial variables accounted for 11.4%, perhaps due to the pronounced abiotic gradients in the alpine areas. Our study highlights the mechanism of plant community assembly in the alpine ecosystem, where environmental filtering plays a more important role than dispersal limitation. In addition, a reasonably controlled abundance of Compositae (the family with the highest niche breadth and large niche overlap value with Gramineae and Cyperaceae) was expected to maintain sustainable development in pastoral production. These results suggest that management measures should be developed with the goal of improving or maintaining suitable local environmental conditions.
Project description:Detailed offline speciation of gas- and particle-phase organic compounds was conducted using gas/liquid chromatography with traditional and high-resolution mass spectrometers in a hybrid targeted/nontargeted analysis. Observations were focused on an unoccupied home and were compared to two other indoor sites. Observed gas-phase organic compounds span the volatile to semivolatile range, while functionalized organic aerosols extend from intermediate volatility to ultra-low volatility, including a mix of oxygen, nitrogen, and sulfur-containing species. Total gas-phase abundances of hydrocarbon and oxygenated gas-phase complex mixtures were elevated indoors and strongly correlated in the unoccupied home. While gas-phase concentrations of individual compounds generally decreased slightly with greater ventilation, their elevated ratios relative to controlled emissions of tracer species suggest that the dilution of gas-phase concentrations increases off-gassing from surfaces and other indoor reservoirs, with volatility-dependent responses to dynamically changing environmental factors. Indoor-outdoor emissions of gas-phase intermediate-volatility/semivolatile organic hydrocarbons from the unoccupied home averaged 6-11 mg h-1, doubling with ventilation. While the largest single-compound emissions observed were furfural (61-275 mg h-1) and acetic acid, observations spanned a wide range of individual volatile chemical products (e.g., terpenoids, glycol ethers, phthalates, other oxygenates), highlighting the abundance of long-lived reservoirs resulting from prior indoor use or materials, and their gradual transport outdoors.
Project description:For healthcare centers, local outdoor sources of air pollution represent a potential threat to indoor air quality (IAQ). The aim of this study was to study the impact of local outdoor sources of air pollution on the IAQ of a university hospital. IAQ was characterized at thirteen indoor and two outdoor locations and source samples were collected from a helicopter and an emergency power supply. Volatile organic compounds (VOC), acrolein, formaldehyde, nitrogen dioxide (NO₂), respirable particulate matter (PM-4.0 and PM-2.5) and their respective benz(a)pyrene contents were determined over a period of two weeks. Time-weighted average concentrations of NO₂ (4.9-17.4 μg/m³) and formaldehyde (2.5-6.4 μg/m³) were similar on all indoor and outdoor locations. The median concentration VOC in indoor air was 119 μg/m³ (range: 33.1-2450 μg/m³) and was fivefold higher in laboratories (316 μg/m³) compared to offices (57.0 μg/m³). PM-4.0 and benzo(a)pyrene concentration were lower in buildings serviced by a >99.95% efficiency particle filter, compared to buildings using a standard 80-90% efficiency filter (p < 0.01). No indications were found that support a significant contribution of known local sources such as fuels or combustion engines to any of the IAQ parameters measured in this study. Chemical IAQ was primarily driven by known indoor sources and activities.