Convenient, rapid and accurate measurement of SVOC emission characteristics in experimental chambers.
Ontology highlight
ABSTRACT: Chamber tests are usually used to determine the source characteristics of semi-volatile organic compounds (SVOCs) which are critical to quantify indoor exposure to SVOCs. In contrast to volatile organic compounds (VOCs), the sorption effect of SVOCs to chamber surfaces usually needs to be considered due to the much higher surface/air partition coefficients, resulting in a long time to reach steady state, frequently on the order of months, and complicating the mathematical analysis of the resulting data. A chamber test is also complicated if the material-phase concentration is not constant. This study shows how to design a chamber to overcome these limitations. A dimensionless mass transfer analysis is used to specify conditions for (1) neglecting the SVOC sorption effect to chamber surface
SUBMITTER: Liu C
PROVIDER: S-EPMC3756072 | biostudies-literature | 2013
REPOSITORIES: biostudies-literature