Adjustment for measurement error in evaluating diagnostic biomarkers by using an internal reliability sample.
Ontology highlight
ABSTRACT: Biomarkers are often measured with error due to imperfect lab conditions or temporal variability within subjects. Using an internal reliability sample of the biomarker, we develop a parametric bias-correction approach for estimating a variety of diagnostic performance measures including sensitivity, specificity, the Youden index with its associated optimal cut-point, positive and negative predictive values, and positive and negative diagnostic likelihood ratios when the biomarker is subject to measurement error. We derive the asymptotic properties of the proposed likelihood-based estimators and show that they are consistent and asymptotically normally distributed. We propose confidence intervals for these estimators and confidence bands for the receiver operating characteristic curve. We d
SUBMITTER: White MT
PROVIDER: S-EPMC3808490 | biostudies-literature | 2013 Nov
REPOSITORIES: biostudies-literature
ACCESS DATA