Ontology highlight
ABSTRACT: Background
Dried blood spots (DBS) have been used as alternative specimens to plasma to increase access to HIV viral load (VL) monitoring and early infant diagnosis (EID) in remote settings. We systematically reviewed evidence on the performance of DBS compared to plasma for VL monitoring and EID.Methods and findings
Thirteen peer reviewed HIV VL publications and five HIV EID papers were included. Depending on the technology and the viral load distribution in the study population, the percentage of DBS samples that are within 0.5 log of VL in plasma ranged from 52-100%. Because the input sample volume is much smaller in a blood spot, there is a risk of false negatives with DBS. Sensitivity of DBS VL was found to be 78-100% compared to plasma at VL below 1000 copies/ml, but
SUBMITTER: Smit PW
PROVIDER: S-EPMC3945725 | biostudies-literature | 2014
REPOSITORIES: biostudies-literature