Unknown

Dataset Information

Developing a risk model for in-hospital adverse events following implantable cardioverter-defibrillator implantation: a report from the NCDR (National Cardiovascular Data Registry).


ABSTRACT:

Objectives

To better inform patients and physicians of the expected risk of adverse events and to assist hospitals' efforts to improve the outcomes of patients undergoing implantable cardioverter-defibrillator (ICD) implantation, we developed and validated a risk model using data from the NCDR (National Cardiovascular Data Registry) ICD Registry.

Background

ICD prolong life in selected patients, but ICD implantation carries the risk of periprocedural complications.

Methods

We analyzed data from 240,632 ICD implantation procedures between April 1, 2010, and December 31, 2011 in the registry. The study group was divided into a derivation (70%) and a validation (30%) cohort. Multivariable logistic regression was used to identify factors associated with in-hospital advers

SUBMITTER: Dodson JA 

PROVIDER: S-EPMC3954985 | biostudies-literature | 2014 Mar

REPOSITORIES: biostudies-literature