Unknown

Dataset Information

Biomechanical analysis of the human finger extensor mechanism during isometric pressing.


ABSTRACT: This study investigated the effects of the finger extensor mechanism on the bone-to-bone contact forces at the interphalangeal and metacarpal joints and also on the forces in the intrinsic and extrinsic muscles during finger pressing. This was done with finger postures ranging from very flexed to fully extended. The role of the finger extensor mechanism was investigated by using two alternative finger models, one which omitted the extensor mechanism and another which included it. A six-camera three-dimensional motion analysis system was used to capture the finger posture during maximum voluntary isometric pressing. The fingertip loads were recorded simultaneously using a force plate system. Two three-dimensional biomechanical finger models, a minimal model without extensor mechanism and a

SUBMITTER: Hu D 

PROVIDER: S-EPMC3986208 | biostudies-literature | 2014

REPOSITORIES: biostudies-literature