An alternative technical marker set for the pelvis is more repeatable than the standard pelvic marker set.
Ontology highlight
ABSTRACT: Multiple marker sets and models are currently available for assessing pelvic kinematics in gait. Despite the presence of a variety models, there are still debates on their reliability and consistency, and consequently there is no clearly defined standard. Two marker sets were evaluated in this study: the 'Traditional' where markers are placed at the anterior and posterior superior iliac spines (ASISs, PSISs); and the 'Cluster', where a cluster of three orthogonal markers fixed on a rigid based is attached to the sacrum. The two sets were compared with respect to intra and inter session standard deviations of maximum pelvic tilt, obliquity and rotation angles. The repeatability between and within sessions was measured using coefficient of multiple correlation (CMC). Also the similarity betw