Development of a bent Laue beam-expanding double-crystal monochromator for biomedical X-ray imaging.
Ontology highlight
ABSTRACT: The Biomedical Imaging and Therapy (BMIT) beamline at the Canadian Light Source has produced some excellent biological imaging data. However, the disadvantage of a small vertical beam limits its usability in some applications. Micro-computed tomography (micro-CT) imaging requires multiple scans to produce a full projection, and certain dynamic imaging experiments are not possible. A larger vertical beam is desirable. It was cost-prohibitive to build a longer beamline that would have produced a large vertical beam. Instead, it was proposed to develop a beam expander that would create a beam appearing to originate at a source much farther away. This was accomplished using a bent Laue double-crystal monochromator in a non-dispersive divergent geometry. The design and implementation of this be
SUBMITTER: Martinson M
PROVIDER: S-EPMC3998813 | biostudies-literature | 2014 May
REPOSITORIES: biostudies-literature
ACCESS DATA