Dosimetric study of a respiratory gating technique based on four-dimensional computed tomography in non-small-cell lung cancer.
Ontology highlight
ABSTRACT: This study sought to compare the differences in target volumes and dose distributions to the targets and organs at risk (OARs) between a four-dimensional computed tomography (4DCT)-based respiratory-gated intensity-modulated radiation therapy (IMRT) plan (PlanEOE) and a three-dimensional CT (3DCT)-based IMRT plan (Plan3D) in patients with non-small-cell lung cancer (NSCLC). For 17 patients with Stages I-III NSCLC, both 4DCT data and conventional 3DCT data were obtained. The Plan3D and PlanEOE were designed based on 3DCT data and 4DCT data, respectively. The displacements of the gross tumor volume (GTV) centroid were 0.13 ± 0.09 cm, 0.15 ± 0.1 cm, and 0.27 ± 0.27 cm in the right-left, anterior-posterior, and superior-inferior directions, respectively. The volume of the GTVEOE was 3.05 ± 5.1
SUBMITTER: Lin H
PROVIDER: S-EPMC4014168 | biostudies-literature | 2014 May
REPOSITORIES: biostudies-literature
ACCESS DATA