Improving the accuracy and efficiency of respiratory rate measurements in children using mobile devices.


ABSTRACT: The recommended method for measuring respiratory rate (RR) is counting breaths for 60 s using a timer. This method is not efficient in a busy clinical setting. There is an urgent need for a robust, low-cost method that can help front-line health care workers to measure RR quickly and accurately. Our aim was to develop a more efficient RR assessment method. RR was estimated by measuring the median time interval between breaths obtained from tapping on the touch screen of a mobile device. The estimation was continuously validated by measuring consistency (% deviation from the median) of each interval. Data from 30 subjects estimating RR from 10 standard videos with a mobile phone application were collected. A sensitivity analysis and an optimization experiment were performed to verify that a