Ontology highlight
ABSTRACT: Background
Performing optogenetic experiments in a behaving animal presents a unique technical challenge. In order to provide an optical path between a fixed light source and a chronically implanted fiber in a freely moving animal, a typical experimental setup includes a detachable connection between the light source and the head of the animal, as well as a rotary joint to relieve torsional stress during movement.New method
We have combined the functionality of the head mounted connector and the rotary joint into a single integrated device that is inexpensive, simple to build, and easy to use.Results
A typical rotary connector has a transmission efficiency of 80% with a rotational variability of 4%, but can be configured to have a rotational variability of 2% at the
SUBMITTER: Klorig DC
PROVIDER: S-EPMC4122252 | biostudies-literature | 2014 Apr