ABSTRACT: Background
The objective of this study was to determine the effect of inspiratory resistance through an impedance threshold device (ITD) on orthostatic tolerance in patients with postural tachycardia syndrome. We hypothesized that the ITD would result in a greater negative intrathoracic pressure to enhance cardiac venous return, improve stroke volume, and reduce heart rate in these patients.Methods and results
We compared the effect of a sham device (sham, no resistance) versus an ITD (increased inspiratory resistance) in 26 patients with postural tachycardia syndrome in a randomized, single-blind, crossover study. Hemodynamic assessments were performed at baseline while supine and during head-up tilt to 70° for 10 minutes. We did not find differences in baseline hemodynami