Unknown

Dataset Information

Noninvasive biomagnetic detection of intestinal slow wave dysrhythmias in chronic mesenteric ischemia.


ABSTRACT: Chronic mesenteric ischemia (CMI) is a challenging clinical problem that is difficult to diagnose noninvasively. Diagnosis early in the disease process would enable life-saving early surgical intervention. Previous studies established that superconducting quantum interference device (SQUID) magnetometers detect the slow wave changes in the magnetoenterogram (MENG) noninvasively following induction of mesenteric ischemia in animal models. The purpose of this study was to assess functional physiological changes in the intestinal slow wave MENG of patients with chronic mesenteric ischemia. Pre- and postoperative studies were conducted on CMI patients using MENG and intraoperative recordings using invasive serosal electromyograms (EMG). Our preoperative MENG recordings showed that patients wit

SUBMITTER: Somarajan S 

PROVIDER: S-EPMC4491509 | biostudies-literature | 2015 Jul

REPOSITORIES: biostudies-literature