ABSTRACT: Background
Mitral valve (MV) repair using annuloplasty rings is the preferred method of treatment for MV regurgitation, but the impact of annuloplasty ring placement on left ventricular intraventricular flow has not been studied.Methods
Annuloplasty rings of varying sizes were placed in 5 healthy sheep (intercommissural ring sizes were 24, 26, 28, 30, and 32 mm), and three-dimensional phase contrast magnetic resonance imaging (4D flow MRI) was performed before and 1 week after ring placement.Results
Normal diastolic flow consisted of diastolic intraventricular vortices that naturally unwound during systole. Postsurgical intraventricular flow was highly disturbed in all sheep, and the disturbance was greatest for undersized rings. Ring size was highly correlated with
SUBMITTER: Witschey WR
PROVIDER: S-EPMC4492839 | biostudies-literature | 2015 Jul