A Simple and Sensitive Method to Quantify Biodegradable Nanoparticle Biodistribution using Europium Chelates.
Ontology highlight
ABSTRACT: The biodistribution of biodegradable nanoparticles can be difficult to quantify. We report a method using time resolved fluorescence (TRF) from a lanthanide chelate to minimize background autofluorescence and maximize the signal to noise ratio to detect biodegradable nanoparticle distribution in mice. Specifically, antenna chelates containing europium were entrapped within nanoparticles composed of polylactic acid-polyethylene glycol diblock copolymers. Tissue accumulation of nanoparticles following intravenous injection was quantified in mice. The TRF of the nanoparticles was found to diminish as a second order function in the presence of serum and tissue compositions interfered with the europium signal. Both phenomena were corrected by linearization of the signal function and calculation
SUBMITTER: Crawford L
PROVIDER: S-EPMC4561907 | biostudies-literature | 2015 Sep
REPOSITORIES: biostudies-literature
ACCESS DATA