ABSTRACT: Background
Hemodynamic optimization during surgery is of major importance to decrease postoperative morbidity and length of hospital stay. However, conventional cardiac output monitoring is rarely used at the bedside. Recently, the plethysmographic variability index (PVI) was described as a simplified alternative, using plug-and-play noninvasive technology, but its clinical utility remains to be established.Methods/design
The hemodynamic optimization using the PVI (OPVI) trial is a multicenter randomized controlled two-arm trial, randomizing 440 patients at intermediate risk of postoperative complications after orthopedic surgery. Hemodynamic optimization was conducted using either the PVI (PVI group) or conventional mean arterial pressure (control group). The anesthesiolog
SUBMITTER: Fischer MO
PROVIDER: S-EPMC4634899 | biostudies-literature | 2015 Nov