Few Outflow Problems With a Self-locating Catheter for Peritoneal Dialysis: A Randomized Trial.


ABSTRACT: We developed a technique for direct start of peritoneal dialysis. Using a coiled or straight Tenckhoff catheter often results in obstruction of flow. A self-locating Wolfram catheter is on the market. It is not clarified if this results in a benefit.The primary aim of this study was to perform a randomized investigation to clarify if the use of a self-locating peritoneal dialysis (PD) catheter would result in different flow problems than a straight Tenckhoff catheter.A total of 61 insertions were made who were randomized and received either a straight Tenckhoff (n = 32) or a self-locating Wolfram catheter (n = 29). A previously described operation technique allowed immediate postoperative start of dialysis. Seven straight Tenckhoff catheters had to be changed into self-locating catheters, and none vice versa, due to flow problems (P = 0.011). An early leakage resulted in temporarily postponed PD in 4 patients. This study showed that using the present operation technique the self-locating PD-catheter causes fewer obstruction episodes than a straight Tenckhoff catheter. This facilitates immediate postoperative start of PD.

SUBMITTER: Stegmayr BG 

PROVIDER: S-EPMC4674194 | biostudies-literature | 2015 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Few Outflow Problems With a Self-locating Catheter for Peritoneal Dialysis: A Randomized Trial.

Stegmayr Bernd G BG   Sperker Wolfgang W   Nilsson Christina H CH   Degerman Christina C   Persson Sven-Erik SE   Stenbaek Jan J   Arnerlöv Conny C  

Medicine 20151201 48


We developed a technique for direct start of peritoneal dialysis. Using a coiled or straight Tenckhoff catheter often results in obstruction of flow. A self-locating Wolfram catheter is on the market. It is not clarified if this results in a benefit.The primary aim of this study was to perform a randomized investigation to clarify if the use of a self-locating peritoneal dialysis (PD) catheter would result in different flow problems than a straight Tenckhoff catheter.A total of 61 insertions wer  ...[more]

Similar Datasets

| S-EPMC6226827 | biostudies-literature
2020-01-24 | GSE57070 | GEO
| S-EPMC7403557 | biostudies-literature
| S-EPMC9971291 | biostudies-literature
| S-EPMC6586404 | biostudies-literature
| S-EPMC10719604 | biostudies-literature
| S-EPMC7879110 | biostudies-literature
| S-EPMC7374195 | biostudies-literature
| S-EPMC7590605 | biostudies-literature