Pulmonary and cardiovascular responses of rats to inhalation of a commercial antimicrobial spray containing titanium dioxide nanoparticles.
Ontology highlight
ABSTRACT: Our laboratory has previously demonstrated that application of an antimicrobial spray product containing titanium dioxide (TiO(2)) generates an aerosol of titanium dioxide in the breathing zone of the applicator. The present report describes the design of an automated spray system and the characterization of the aerosol delivered to a whole body inhalation chamber. This system produced stable airborne levels of TiO(2) particles with a median count size diameter of 110 nm. Rats were exposed to 314 mg/m(3) min (low dose), 826 mg/m(3) min (medium dose), and 3638 mg/m(3) min (high dose) of TiO(2) under the following conditions: 2.62 mg/m(3) for 2 h, 1.72 mg/m(3) 4 h/day for 2 days, and 3.79 mg/m(3) 4 h/day for 4 days, respectively. Pulmonary (breathing rate, specific airway resistance, inflamm
SUBMITTER: McKinney W
PROVIDER: S-EPMC4683931 | biostudies-literature | 2012 Jun
REPOSITORIES: biostudies-literature
ACCESS DATA