Unknown

Dataset Information

0

Working volume: validity evidence for a motion-based metric of surgical efficiency.


ABSTRACT:

Background

The aim of this study was to evaluate working volume as a potential assessment metric for open surgical tasks.

Methods

Surgical attendings (n = 6), residents (n = 4), and medical students (n = 5) performed a suturing task on simulated connective tissue (foam), artery (rubber balloon), and friable tissue (tissue paper). Using a motion tracking system, effective working volume was calculated for each hand. Repeated measures analysis of variance assessed differences in working volume by experience level, dominant and/or nondominant hand, and tissue type.

Results

Analysis revealed a linear relationship between experience and working volume. Attendings had the smallest working volume, and students had the largest (P = .01). The 3-way interaction of experience level, hand, and material type showed attendings and residents maintained a similar working volume for dominant and nondominant hands for all tasks. In contrast, medical students' nondominant hand covered larger working volumes for the balloon and tissue paper materials (P < .05).

Conclusions

This study provides validity evidence for the use of working volume as a metric for open surgical skills. Working volume may provide a means for assessing surgical efficiency and the operative learning curve.

SUBMITTER: D'Angelo AL 

PROVIDER: S-EPMC4724457 | biostudies-literature | 2016 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Working volume: validity evidence for a motion-based metric of surgical efficiency.

D'Angelo Anne-Lise D AL   Rutherford Drew N DN   Ray Rebecca D RD   Laufer Shlomi S   Mason Andrea A   Pugh Carla M CM  

American journal of surgery 20151111 2


<h4>Background</h4>The aim of this study was to evaluate working volume as a potential assessment metric for open surgical tasks.<h4>Methods</h4>Surgical attendings (n = 6), residents (n = 4), and medical students (n = 5) performed a suturing task on simulated connective tissue (foam), artery (rubber balloon), and friable tissue (tissue paper). Using a motion tracking system, effective working volume was calculated for each hand. Repeated measures analysis of variance assessed differences in wor  ...[more]

Similar Datasets

| S-EPMC8248418 | biostudies-literature
| S-EPMC7710115 | biostudies-literature
| S-EPMC10245189 | biostudies-literature
| S-EPMC11864550 | biostudies-literature
| S-EPMC9629630 | biostudies-literature
| S-EPMC9922454 | biostudies-literature
| S-EPMC11329219 | biostudies-literature
| S-EPMC11227719 | biostudies-literature
| S-EPMC9870814 | biostudies-literature
| S-EPMC6862302 | biostudies-literature