The design and validation of an optical coherence tomography-based classification system for focal vitreomacular traction.


ABSTRACT:

Purpose

To develop and validate a classification system for focal vitreomacular traction (VMT) with and without macular hole based on spectral domain optical coherence tomography (SD-OCT), intended to aid in decision-making and prognostication.

Methods

A panel of retinal specialists convened to develop this system. A literature review followed by discussion on a wide range of cases formed the basis for the proposed classification. Key features on OCT were identified and analysed for their utility in clinical practice. A final classification was devised based on two sequential, independent validation exercises to improve interobserver variability.

Results

This classification tool pertains to idiopathic focal VMT assessed by a horizontal line scan using SD-OCT. The syst

SUBMITTER: Steel DH 

PROVIDER: S-EPMC4763137 | biostudies-literature | 2016 Feb

REPOSITORIES: biostudies-literature