Simulation of air quality and cost to ventilate swine farrowing facilities in winter.
Ontology highlight
ABSTRACT: We developed a simulation model to study the effect of ventilation airflow rate with and without filtered recirculation on airborne contaminant concentrations (dust, NH3, CO, and CO2) for swine farrowing facilities. Energy and mass balance equations were used to simulate the indoor air quality and operational cost for a variety of ventilation conditions over a 3-month winter period, using time-varied outdoor temperature. The sensitivity of input and output parameters on indoor air quality and operational cost were evaluated. Significant factors affecting model output included mean winter temperature, generation rate of contaminants, pit-air-exchange ratio, and recirculation ratio. As mean outdoor temperature was decreased from -2.5 °C to -12.5 °C, total operational co
SUBMITTER: Park JH
PROVIDER: S-EPMC4770838 | biostudies-literature | 2013 Oct
REPOSITORIES: biostudies-literature
ACCESS DATA