Unknown

Dataset Information

Design and computational fluid dynamics investigation of a personal, high flow inhalable sampler.


ABSTRACT: The objective of this research was to develop an inlet to meet the inhalable sampling criterion at 10 l min(-1) flow using the standard, 37-mm cassette. We designed a porous head for this cassette and evaluated its performance using computational fluid dynamics (CFD) modeling. Particle aspiration efficiency was simulated in a wind tunnel environment at 0.4 m s(-1) freestream velocity for a facing-the-wind orientation, with sampler oriented at both 0 degrees (horizontal) and 30 degrees down angles. The porous high-flow sampler oriented 30 degrees downward showed reasonable agreement with published mannequin wind tunnel studies and humanoid CFD investigations for solid particle aspiration into the mouth, whereas the horizontal orientation resulted in oversampling. Liquid particles were under

SUBMITTER: Anthony TR 

PROVIDER: S-EPMC4780251 | biostudies-literature | 2010 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Sorry, this publication's infomation has not been loaded in the Indexer, please go directly to PUBMED or Altmetric.

Similar Datasets