Goldmann visual fields (GVFs) are useful for tracking changes in areas of functional retina, including the periphery, in inherited retinal degeneration patients. Quantitative GVF analysis requires digitization of the chart coordinates for the main axes and isopter points marked by the GVF operator during testing. This study investigated inter- and intra-digitizer variability among users of a manual GVF digitization program.Methods
Ten digitizers were trained for 1 hour, then digitized 23 different GVFs from inherited retinal degeneration patients in each of three testing blocks. Digitizers labeled each isopter as seeing or non-seeing, and its target size. Isopters with the same test target within each GVF were grouped to create isopter groups.Results
The sta