Unknown

Dataset Information

Mechanism of the entire overdischarge process and overdischarge-induced internal short circuit in lithium-ion batteries.


ABSTRACT: Lithium-ion batteries connected in series are prone to be overdischarged. Overdischarge results in various side effects, such as capacity degradation and internal short circuit (ISCr). However, most of previous research on the overdischarge of a cell was terminated when the cell voltage dropped to 0 V, leaving the further impacts of overdischarge unclear. This paper investigates the entire overdischarge process of large-format lithium-ion batteries by discharging the cell to -100% state of charge (SOC). A significant voltage platform is observed at approximately -12% SOC, and ISCr is detected after the cell is overdischarged when passing the platform. The scanning electron microscopy (SEM) and X-ray diffraction (XRD) results indicate that the overdischarge-induced ISCr is caused by Cu depo

SUBMITTER: Guo R 

PROVIDER: S-EPMC4957210 | biostudies-literature | 2016 Jul

REPOSITORIES: biostudies-literature