Unknown

Dataset Information

0

Full data acquisition in Kelvin Probe Force Microscopy: Mapping dynamic electric phenomena in real space.


ABSTRACT: Kelvin probe force microscopy (KPFM) has provided deep insights into the local electronic, ionic and electrochemical functionalities in a broad range of materials and devices. In classical KPFM, which utilizes heterodyne detection and closed loop bias feedback, the cantilever response is down-sampled to a single measurement of the contact potential difference (CPD) per pixel. This level of detail, however, is insufficient for materials and devices involving bias and time dependent electrochemical events; or at solid-liquid interfaces, where non-linear or lossy dielectrics are present. Here, we demonstrate direct recovery of the bias dependence of the electrostatic force at high temporal resolution using General acquisition Mode (G-Mode) KPFM. G-Mode KPFM utilizes high speed detection, compression, and storage of the raw cantilever deflection signal in its entirety at high sampling rates. We show how G-Mode KPFM can be used to capture nanoscale CPD and capacitance information with a temporal resolution much faster than the cantilever bandwidth, determined by the modulation frequency of the AC voltage. In this way, G-Mode KPFM offers a new paradigm to study dynamic electric phenomena in electroactive interfaces as well as a promising route to extend KPFM to the solid-liquid interface.

SUBMITTER: Collins L 

PROVIDER: S-EPMC4981877 | biostudies-literature | 2016 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Full data acquisition in Kelvin Probe Force Microscopy: Mapping dynamic electric phenomena in real space.

Collins Liam L   Belianinov Alex A   Somnath Suhas S   Balke Nina N   Kalinin Sergei V SV   Jesse Stephen S  

Scientific reports 20160812


Kelvin probe force microscopy (KPFM) has provided deep insights into the local electronic, ionic and electrochemical functionalities in a broad range of materials and devices. In classical KPFM, which utilizes heterodyne detection and closed loop bias feedback, the cantilever response is down-sampled to a single measurement of the contact potential difference (CPD) per pixel. This level of detail, however, is insufficient for materials and devices involving bias and time dependent electrochemica  ...[more]

Similar Datasets

| S-EPMC10644032 | biostudies-literature
| S-EPMC4311590 | biostudies-literature
| S-EPMC6009372 | biostudies-literature
| S-EPMC6097802 | biostudies-literature
| S-EPMC10632481 | biostudies-literature
| S-EPMC4685916 | biostudies-literature
| S-EPMC6009450 | biostudies-literature
| S-EPMC7125200 | biostudies-literature
| S-EPMC3190625 | biostudies-other
| S-EPMC10432393 | biostudies-literature