Estimated Risk Level of Unified Stereotactic Body Radiation Therapy Dose Tolerance Limits for Spinal Cord.
Ontology highlight
ABSTRACT: A literature review of more than 200 stereotactic body radiation therapy spine articles from the past 20 years found only a single article that provided dose-volume data and outcomes for each spinal cord of a clinical dataset: the Gibbs 2007 article (Gibbs et al, 2007(1)), which essentially contains the first 100 stereotactic body radiation therapy (SBRT) spine treatments from Stanford University Medical Center. The dataset is modeled and compared in detail to the rest of the literature review, which found 59 dose tolerance limits for the spinal cord in 1-5 fractions. We partitioned these limits into a unified format of high-risk and low-risk dose tolerance limits. To estimate the corresponding risk level of each limit we used the Gibbs 2007 clinical spinal cord dose-volume data for 102 sp
SUBMITTER: Grimm J
PROVIDER: S-EPMC4990135 | biostudies-literature | 2016 Apr
REPOSITORIES: biostudies-literature
ACCESS DATA