Different effectiveness of closed embryo culture system with time-lapse imaging (EmbryoScope(TM)) in comparison to standard manual embryology in good and poor prognosis patients: a prospectively randomized pilot study.


ABSTRACT:

Background

Previously manual human embryology in many in vitro fertilization (IVF) centers is rapidly being replaced by closed embryo incubation systems with time-lapse imaging. Whether such systems perform comparably to manual embryology in different IVF patient populations has, however, never before been investigated. We, therefore, prospectively compared embryo quality following closed system culture with time-lapse photography (EmbryoScope™) and standard embryology. We performed a two-part prospectively randomized study in IVF (clinical trial # NCT92256309). Part A involved 31 infertile poor prognosis patients prospectively randomized to EmbryoScope™ and standard embryology. Part B involved embryos from 17 egg donor-recipient cycles resulting in large egg/embryo numbers, thus p

SUBMITTER: Wu YG 

PROVIDER: S-EPMC4995783 | biostudies-literature | 2016 Aug

REPOSITORIES: biostudies-literature