ABSTRACT: Background
The recently implemented mARC-rotation-technique is capable to deliver high dose rate bursts. For the case of hypopharynx cancer plans we evaluate whether the mARC can achieve an advantage in treatment time in comparison to IMRT. These plans consider two arcs with flat and flattening filter free (FFF) beam energies.Materials and methods
For 8 hypopharynx-cancer patients step-and-shoot-IMRT and mARC plans were created retrospectively using flat and FFF beam energy. The comparison of the plan scenarios considered measures of quality for PTV coverage and sparing of organs at risk. All plans were irradiated on an anthromorphic phantom equipped with thermoluminescent dosimeters to measure scattered dose and treatment times.Results
A visual comparison of the do