Trends and determinant factors in the use of cardiac resynchronization therapy devices in Japan: Analysis of the Japan cardiac device treatment registry database.


ABSTRACT: BACKGROUND:The choice of cardiac resynchronization therapy device, with (CRT-D) or without (CRT-P) a defibrillator, in patients with heart failure largely depends on the physician?s discretion, because it has not been established which subjects benefit most from a defibrillator. METHODS:We examined the annual trend of CRT device implantations between 2006 and 2014, and evaluated the factors related to the device selection (CRT-D or CRT-P) for primary prevention of sudden cardiac death in patients with heart failure by analyzing the Japan Cardiac Device Treatment Registry (JCDTR) database from January 2011 and August 2015 (CRT-D, n=2714; CRT-P, n=555). RESULTS:The proportion of CRT-D implantations for primary prevention among all the CRT-D recipients was more than 70% during the study period. The number of CRT-D implantations for primary prevention reached a maximum in 2011 and decreased gradually between 2011 and 2014, whereas CRT-P implantations increased year by year until 2011 and remained unchanged in recent years. Multivariate analysis identified age (odds ratio [OR] 0.92, 95% confidence interval [CI] 0.90-0.95, P<0.0001), male sex (OR 1.99, 95% CI 1.28-3.11, P<0.005), reduced left ventricular ejection fraction (LVEF) (OR 0.96, 95% CI 0.94-0.98, P<0.0001), and non-sustained ventricular tachycardia (NSVT) (OR 2.85, 95% CI 1.87-4.35, P<0.0001) as independent factors favoring the choice of CRT-D. CONCLUSIONS:Younger age, male sex, reduced LVEF, and a history of NSVT were independently associated with the choice of CRT-D for primary prevention of sudden cardiac death in patients with heart failure in Japan.

SUBMITTER: Yokoshiki H 

PROVIDER: S-EPMC5129119 | biostudies-literature | 2016 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Trends and determinant factors in the use of cardiac resynchronization therapy devices in Japan: Analysis of the Japan cardiac device treatment registry database.

Yokoshiki Hisashi H   Shimizu Akihiko A   Mitsuhashi Takeshi T   Furushima Hiroshi H   Sekiguchi Yukio Y   Manaka Tetsuyuki T   Nishii Nobuhiro N   Ueyama Takeshi T   Morita Norishige N   Nitta Takashi T   Okumura Ken K  

Journal of arrhythmia 20160429 6


<h4>Background</h4>The choice of cardiac resynchronization therapy device, with (CRT-D) or without (CRT-P) a defibrillator, in patients with heart failure largely depends on the physician׳s discretion, because it has not been established which subjects benefit most from a defibrillator.<h4>Methods</h4>We examined the annual trend of CRT device implantations between 2006 and 2014, and evaluated the factors related to the device selection (CRT-D or CRT-P) for primary prevention of sudden cardiac d  ...[more]

Similar Datasets

| S-EPMC10848589 | biostudies-literature
| S-EPMC11730701 | biostudies-literature
| S-EPMC10549811 | biostudies-literature
| S-EPMC6931796 | biostudies-literature
| S-EPMC4943256 | biostudies-literature
| S-EPMC8523028 | biostudies-literature
| S-EPMC5259807 | biostudies-literature
| S-EPMC7896472 | biostudies-literature
| S-EPMC10406527 | biostudies-literature
| S-EPMC5814986 | biostudies-literature