Guided wave tomography with an improved scattering model.


ABSTRACT: Producing accurate thickness maps of corrosion damage is of great importance for assessing life in the petrochemical industry. Guided wave tomography provides a solution for this, by sending guided waves through the region of interest, then using tomographic imaging techniques to reconstruct the thickness map, importantly eliminating the need to take measurements at all points across the surface. However, to achieve accurate maps, the imaging algorithm must account for the way in which the guided waves interact with corrosion defects, and the complex scattering which occurs. Traditional approaches have exploited the dispersive nature of guided waves: a velocity map is produced from a dataset, then converted to thickness using the dispersion relationship. However, these relationships are de