Development and Validation of a UAV Based System for Air Pollution Measurements.
Ontology highlight
ABSTRACT: Air quality data collection near pollution sources is difficult, particularly when sites are complex, have physical barriers, or are themselves moving. Small Unmanned Aerial Vehicles (UAVs) offer new approaches to air pollution and atmospheric studies. However, there are a number of critical design decisions which need to be made to enable representative data collection, in particular the location of the air sampler or air sensor intake. The aim of this research was to establish the best mounting point for four gas sensors and a Particle Number Concentration (PNC) monitor, onboard a hexacopter, so to develop a UAV system capable of measuring point source emissions. The research included two different tests: (1) evaluate the air flow behavior of a hexacopter, its downwash and upwash effect,
SUBMITTER: Villa TF
PROVIDER: S-EPMC5191180 | biostudies-literature | 2016 Dec
REPOSITORIES: biostudies-literature