Comparison of biological H2S removal characteristics between a composite packing material with and without functional microorganisms.
Ontology highlight
ABSTRACT: The performances of two identical biofilters, filled with a new composite packing material (named CM-5) embedded with functional microorganisms or sterilized CM-5 without microorganisms, were investigated for H2S treatment. Running parameters in terms of microbial counts, pressure drops, and inlet and outlet H2S concentrations were measured. The results show that the microbial count of the CM-5 was approximately ×105 CFU/g before being filled into the biofilter, while that of the sterilized CM-5 was negligible. The functional microorganisms embedded in CM-5 adapted to the environment containing H2S quickly. In most cases, pressure drops of the CM-5 biofilter were slightly higher than those of the sterilized CM-5 biofilter when the gas flow rate w
SUBMITTER: Zhu R
PROVIDER: S-EPMC5304181 | biostudies-literature | 2017 Feb
REPOSITORIES: biostudies-literature
ACCESS DATA