A Simple Method for Noninvasive Quantification of Pressure Gradient Across the Pulmonary Valve.
Ontology highlight
ABSTRACT: Pressure gradient across the pulmonary valve (PVPG) is an important hemodynamic variable used in the management of patients with cardiovascular and pulmonary disease. However, a reliable noninvasive method is unavailable. We hypothesized that a progressive Muller maneuver would elicit the pulmonary valve premature opening (PVPO) in diastole and that this event would be detectable by Doppler echocardiography. The intrathoracic pressure (ITP) decrease during this maneuver equals PVPG, which may be assessed with a custom airway pressure measurement device. A total of 102 subjects were enrolled in the study. At the earliest appearance of PVPO, the ITP decrease was recorded as the PVPG. PVPG was also simultaneously measured and compared by other two methods: right heart catheterization in 43 su
SUBMITTER: Zhou X
PROVIDER: S-EPMC5309885 | biostudies-literature | 2017 Feb