Predicting deliverability of volumetric-modulated arc therapy (VMAT) plans using aperture complexity analysis.
Ontology highlight
ABSTRACT: The purpose of this study was to evaluate the ability of an aperture complexity metric for volumetric-modulated arc therapy (VMAT) plans to predict plan delivery accuracy. We developed a complexity analysis tool as a plug-in script to Varian's Eclipse treatment planning system. This script reports the modulation of plans, arcs, and individual control points for VMAT plans using a previously developed complexity metric. The calculated complexities are compared to that of 649 VMAT plans previously treated at our institution from 2013 to mid-2015. We used the VMAT quality assurance (QA) results from the 649 treated plans, plus 62 plans that failed pretreatment QA, to validate the ability of the complexity metric to predict plan deliverability. We used a receiver operating characteristic (ROC)
SUBMITTER: Younge KC
PROVIDER: S-EPMC5345484 | biostudies-literature | 2016 Jul
REPOSITORIES: biostudies-literature