Unknown

Dataset Information

Midterm analysis of the seleXys cup with ceramic inlay.


ABSTRACT:

Background

Ceramic-on-ceramic (CoC) articulations in total hip replacement (THR) has been accepted as giving reliable mid-term results; however recent studies have reported higher revision rates of some implants. This study analyses the nationwide results of the seleXys TPS cup and the Bionit2 liner (Mathys, Bettlach, Switzerland) with respect to implant survival, cause for revision and mortality rates compared to other CoC articulations using the same stem.

Methods

Utilising the New Zealand Joint Registry, we compared the seleXys TPS cup with Bionit2 liner used with an uncemented Twinsys femoral stem to every other uncemented CoC THR using the same stem. Multivariate analysis was used to determine the effects of patient age, gender, ASA score and implant head size on these

SUBMITTER: Halasi T 

PROVIDER: S-EPMC5585767 | biostudies-literature | 2017 Sep

REPOSITORIES: biostudies-literature