Unknown

Dataset Information

Undetectable Concentrations of a Food and Drug Administration-approved High-sensitivity Cardiac Troponin T Assay to Rule Out Acute Myocardial Infarction at Emergency Department Arrival.


ABSTRACT:

Background

The objective of this study was to quantify the sensitivity of very low concentrations of high-sensitivity cardiac troponin T (hsTnT) at ED arrival for acute myocardial infarction (AMI) in a large cohort of chest pain patients evaluated in real-world clinical practice.

Methods

This retrospective study included consecutive ED patients with suspected cardiac chest pain evaluated in four urban EDs, excluding those with ST-elevation AMI, cardiac arrest or abnormal kidney function. The primary outcomes were AMI at 7, 30, and 90 days. Secondary outcomes included major adverse cardiac events (MACE; all-cause mortality, AMI, and revascularization) and the individual MACE components. Test characteristics were calculated for hsTnT values from 3 to 200 ng/L .

Results

SUBMITTER: McRae AD 

PROVIDER: S-EPMC5656889 | biostudies-literature | 2017 Oct

REPOSITORIES: biostudies-literature