Unknown

Dataset Information

Metal-on-Metal Hip Joint Prostheses: a Retrospective Case Series Investigating the Association of Systemic Toxicity with Serum Cobalt and Chromium Concentrations.


ABSTRACT:

Introduction

There have been concerns about prosthesis failure and the potential for systemic toxicity due to release of cobalt and chromium from metal-on-metal hip joint prostheses (MoM-HP). There is conflicting evidence on whether there is a correlation between higher cobalt and chromium concentrations and systemic toxicity.

Methods

We undertook a retrospective review of consecutive patients with MoM-HP referred for outpatient review in toxicology clinics in London, UK, and in the USA recorded in the Toxicology Investigators Consortium (ToxIC) Registry from June 2011 to June 2015.

Results

Thirty-one cases were identified; the median (IQR) serum cobalt concentration was 10.0 (3.8-32.8) mcg/L, and the median (IQR) serum chromium concentration was 6.9 (3.7-18.7) mcg/L.

SUBMITTER: Ho JH 

PROVIDER: S-EPMC5711759 | biostudies-literature | 2017 Dec

REPOSITORIES: biostudies-literature