INTERMACS Analysis of Stroke During Support With Continuous-Flow Left Ventricular Assist Devices: Risk Factors and Outcomes.


ABSTRACT:

Objectives

This study sought to evaluate predictors of stroke during left ventricular assist device (LVAD) support from data available prior to implantation, and quantify stroke-related morbidity and mortality.

Background

Stroke is a major complication after LVAD. Pre-implant factors that influence stroke are not well understood.

Methods

We evaluated all patients in INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) who were implanted with continuous flow LVADs from May 1, 2012, to March 31, 2015. Pre-operative risk factors for stroke and stroke incidence, morbidity, and mortality were analyzed.

Results

During the study period, 7,112 patients underwent continuous flow LVAD placement. Median follow-up was 9.79 months (range 0.02 to 34

SUBMITTER: Acharya D 

PROVIDER: S-EPMC5743224 | biostudies-literature | 2017 Oct