Unknown

Dataset Information

Exploring an optimal wavelet-based filter for cryo-ET imaging.


ABSTRACT: Cryo-electron tomography (cryo-ET) is one of the most advanced technologies for the in situ visualization of molecular machines by producing three-dimensional (3D) biological structures. However, cryo-ET imaging has two serious disadvantages-low dose and low image contrast-which result in high-resolution information being obscured by noise and image quality being degraded, and this causes errors in biological interpretation. The purpose of this research is to explore an optimal wavelet denoising technique to reduce noise in cryo-ET images. We perform tests using simulation data and design a filter using the optimum selected wavelet parameters (three-level decomposition, level-1 zeroed out, subband-dependent threshold, a soft-thresholding and spline-based discrete dyadic wavelet transform (

SUBMITTER: Huang X 

PROVIDER: S-EPMC5803242 | biostudies-literature | 2018 Feb

REPOSITORIES: biostudies-literature