Unknown

Dataset Information

Real-time energy/mass transfer mapping for online 4D dose reconstruction.


ABSTRACT: In this work we describe an ultra-fast, low-latency implementation of the energy/mass transfer (EMT) mapping method to accumulate dose on deforming geometries such as lung using the central processing unit (CPU). It enables the computation of the actually delivered dose for intensity-modulated radiation therapy on 4D image data in real-time at 25 Hz. In order to accumulate the delivered dose onto a reference phase a pre-calculated deformable vector field is used. The aim of this study is to present an online dose accumulation technique that can be carried out in less than 40 ms to accommodate the machine log update rate of our research linac. Three speed optimisation strategies for the CPU are discussed: single-core optimisation, parallelisation for multiple cores and vectorisation. The si

SUBMITTER: Ziegenhein P 

PROVIDER: S-EPMC5827544 | biostudies-literature | 2018 Feb

REPOSITORIES: biostudies-literature