A two-pool kinetic model predicts phosphate concentrations during and shortly following a conventional (three times weekly) hemodialysis session.


ABSTRACT:

Background

Previous studies have suggested that a conventional two-pool model cannot be used to predict intradialysis and early postdialysis phosphorus concentrations.

Methods

A conventional two-pool urea model was modified by increasing the distal compartment volume from two-thirds to three times the total body water and by the use of a dynamically variable intercompartmental phosphorus clearance during dialysis. The phosphate solver model parameters were derived from an examination of the results in the literature, and fine-tuned using a training set (F4) of 415 Hemodialysis (HEMO) Study patients studied during a dialysis session where phosphorus was measured at 4 months of follow-up. Validation was done in a group of 380 different HEMO Study patients plus 9 from the origi