Translating bed total body irradiation lung shielding and dose optimization using asymmetric MLC apertures.
Ontology highlight
ABSTRACT: A revised translating bed total body irradiation (TBI) technique is developed for shielding organs at risk (lungs) to tolerance dose limits, and optimizing dose distribution in three dimensions (3D) using an asymmetrically-adjusted, dynamic multileaf collimator. We present a dosimetric comparison of this technique with a previously developed symmetric MLC-based TBI technique. An anthropomor-phic RANDO phantom is CT scanned with 3 mm slice thickness. Radiological depths (RD) are calculated on individual CT slices along the divergent ray lines. Asymmetric MLC apertures are defined every 9 mm over the phantom length in the craniocaudal direction. Individual asymmetric MLC leaf positions are optimized based on RD values of all slices for uniform dose distributions. Dose calculations are perfor
SUBMITTER: Ahmed S
PROVIDER: S-EPMC5875554 | biostudies-literature | 2016 Mar
REPOSITORIES: biostudies-literature