Present-day monitoring underestimates the risk of exposure to pathogenic bacteria from cold water storage tanks.
Ontology highlight
ABSTRACT: Water-borne bacteria, found in cold water storage tanks, are causative agents for various human infections and diseases including Legionnaires' disease. Consequently, regular microbiological monitoring of tank water is undertaken as part of the regulatory framework used to control pathogenic bacteria. A key assumption is that a small volume of water taken from under the ball valve (where there is easy access to the stored water) will be representative of the entire tank. To test the reliability of this measure, domestic water samples taken from different locations of selected tanks in London properties between November 2015 and July 2016 were analysed for TVCs, Pseudomonas and Legionella at an accredited laboratory, according to regulatory requirements. Out of ~6000 tanks surveyed, only 15
SUBMITTER: Peter A
PROVIDER: S-EPMC5896965 | biostudies-literature | 2018
REPOSITORIES: biostudies-literature
ACCESS DATA