Unknown

Dataset Information

Optimization of training periods for the estimation model of three-dimensional target positions using an external respiratory surrogate.


ABSTRACT:

Background

During therapeutic beam irradiation, an unvisualized three-dimensional (3D) target position should be estimated using an external surrogate with an estimation model. Training periods for the developed model with no additional imaging during beam irradiation were optimized using clinical data.

Methods

Dual-source 4D-CBCT projection data for 20 lung cancer patients were used for validation. Each patient underwent one to three scans. The actual target positions of each scan were equally divided into two equal parts: one for the modeling and the other for the validating session. A quadratic target position estimation equation was constructed during the modeling session. Various training periods for the session-i.e., modeling periods (TM)-were employed: T

SUBMITTER: Iramina H 

PROVIDER: S-EPMC5909266 | biostudies-literature | 2018 Apr

REPOSITORIES: biostudies-literature