Cardiac resynchronization therapy (CRT) is an established therapy for appropriately selected patients with heart failure. Response to CRT has been heterogeneously defined using both clinical and echocardiographic measures, with poor correlation between the two.Methods
The study cohort was comprised of 202 CRT-treated patients and CRT response was defined at 6 months post-implant. Echocardiographic response (E+) was defined as a reduction in LVESV ≥ 15%, clinical response as an improvement of ≥ 1 NYHA class (C+), and biomarker response as a ≥ 25% reduction in NT-proBNP(B+). The association of response measures (E+, B+, C+; response score range 0-3) and clinical endpoints at 3 years was assessed in landmarked Cox models.Results