Optimizing Column Length and Particle Size in Preparative Batch Chromatography Using Enantiomeric Separations of Omeprazole and Etiracetam as Models: Feasibility of Taguchi Empirical Optimization.
Ontology highlight
ABSTRACT: The overreaching purpose of this study is to evaluate new approaches for determining the optimal operational and column conditions in chromatography laboratories, i.e., how best to select a packing material of proper particle size and how to determine the proper length of the column bed after selecting particle size. As model compounds, we chose two chiral drugs for preparative separation: omeprazole and etiracetam. In each case, two maximum allowed pressure drops were assumed: 80 and 200 bar. The processes were numerically optimized (mechanistic modeling) with a general rate model using a global optimization method. The numerical predictions were experimentally verified at both analytical and pilot scales. The lower allowed pressure drop represents the use of standard equipm